Tecnologia em Metalurgia, Materiais e Mineração
https://tecnologiammm.com.br/doi/10.4322/2176-1523.0887
Tecnologia em Metalurgia, Materiais e Mineração
Artigo Original

LASER INDUCED – BREAKDOWN SPECTROSCOPY FOR QUANTITATIVE Sn AND Nb ANALYSIS IN Zr BASED ALLOYS

CURVAS DE CALIBRAÇÃO DE Sn E Nb EM Zr E LIGAS DE Zr POR ESPECTROSCOPIA - INDUZIDA POR LASER.

Iofrida, Martín; Carricondo, Juan; Ararat, Carlos; Iribarren, Manuel; Corvalán, Carolina

Downloads: 0
Views: 6773

Abstract

Laser induced breakdown spectroscopy (LIBS) calibration curves for SnZr and NbZr alloys were obtained. Relationships between the atomic emission lines present in the spectra and the Sn and Nb concentrations of the samples showed a linear behavior. Also Zy-2 standards were measured to contrast the behavior of the technique in different kind of alloys. The choice of proper Sn,Nb and Zr lines and the equipment´s parameters, such as “integration start delay” and the spectrometer height, were fundamental to enhance the measurements. The samples were analyzed by X-ray fluorescence for a precise determination of their Sn and Nb concentrations.

Keywords

LIBS, ZrSn and ZrNb alloys, Calibration curves, Nuclear.

Resumo

Foram obtidos por espectroscopia a laser (LIBS avaria) curvas de calibração para as ligas de SnZr e NbZr. As relações entre linhas de emissão atômica presentes mostraram um comportamento linear. Zy-2 também foram medidos para comparar as regras de comportamento da arte em diferentes tipos de ligas. A escolha de linhas apropriadas de Sn, Nb e Zr e parâmetros de equipamentos, tais como a “integração de atraso da partida” e a altura do espectrômetro, foram fundamentais para melhorar as medições. Todas as amostras foram analisadas por fluorescência de raios para uma determinação exata das concentrações de Sn e Nb.

Palavras-chave

LIBS, ZrNb ZrSn e ligas, Curvas de calibração, Nuclear.

Referências

1. Gruzin PL, Emelyanov VS, Ryabova GG, Federov GB. Study of the diffusion and distribution of the elements in zirconium and titanium base alloys by the radioactive isotope method. In: Proceedings of the the 2nd Conference on the peaceful uses of atomic energy. 1958.

2. Moan GD, Rudling P. Zirconium in the nuclear industry: thirteenth international symposium. New Jersey: ATSM International; 2002.

3. Suman S, Khan MK, Pathak M, Singh RN, Chakravartty JK. Hydrogen in Zircaloy: mechanism and its impacts. International Journal of Hydrogen Energy. 2015;40(17):5976-5994. http://dx.doi.org/10.1016/j.ijhydene.2015.03.049.

4. Glasstone S, Sesonske A. Nuclear reactor engineering. Barcelona: Reverte; 1990.

5. Burakov VS, Kiris VV, Naumenkov PA, Raikov SN. Calibration free laser spectral analysis of glassesand copper alloys. Journal of Applied Spectroscopy. 2004;71(5):740-746. http://dx.doi.org/10.1023/B:JAPS.0000049638.55151.80.

6. Galbács G, Gornushkin IB, Smith BW, Winefordner JD. Semi-quantitative analysis of binary alloys using laser-induced breakdown spectroscopy and a new calibration approach based on linear correlation. Spectrochimica Acta. Part B, Atomic Spectroscopy. 2001;56(7):1159-1173. http://dx.doi.org/10.1016/S0584-8547(01)00205-1.

7. Barbieri Gonzaga F, Pasquini C. A compact and low cost laser induced breakdown spectroscopic system: Application for simultaneous determination of chromium and nickel in steel using multivariate calibration. Spectrochimica Acta. Part B, Atomic Spectroscopy. 2012;69:20-24. http://dx.doi.org/10.1016/j.sab.2012.02.007.

8. Labutin TA, Popov AM, Raikov SN, Zaytsev SM, Labutina NA, Zorov NB. Determination of chlorine in concrete by laser - induced breakdown spectroscopy in air. Journal of Applied Spectroscopy. 2013;80(3):315-318. http://dx.doi. org/10.1007/s10812-013-9766-8.

9. Chaleard C, Mauchien P, Andre N, Uebbing J, Lacour JL, Geertsen C. Correction of matrix effects in quantitative elemental analysis with laser ablation optical emission Spectrometry. Journal of Analytical Atomic Spectrometry. 1997;12:183-188. http://dx.doi.org/10.1039/a604456e.

10. Rinaldi CA, Ferrero JC. Analysis of Ca in BaCl2 matrix using laser-induced breakdown spectroscopy. Spectrochimica Acta. Part B, Atomic Spectroscopy. 2001;56(8):1419-1429. http://dx.doi.org/10.1016/S0584-8547(01)00256-7.

11. Castle BC, Talabardon K, Smith BW, Winefordner JD. Variables Influencing the Precision of Laser-Induced Breakdown Spectroscopy Measurements. Journal of Applied Spectroscopy. 1998;52(5):649-657. http://dx.doi. org/10.1366/0003702981944300.

12. Smith W. Materials science and engineering. 4th ed. New York: Mac Graw Hill; 2004.

13 Carricondo JI, Iofrida MJ, Corvalán C, Ararat-Ibarguen C, Iribarren M. Primeras mediciones LIBS para determinar curva de calibración en el sistema Zr-Sn de uso nuclear. In: 98° Reunión Nacional de Física. 2013.

14. National Institute of Standards and Technology. Gaithersburg: NIST Electronic Database. 2013 [cited 2013 Sept 13]. Available at: http://www.nist.gov/pml/data/handbook/index.cfm.

15. Bassiotis I, Diamantopoulou A, Giannoudakos A, Roubani-Kalantzopoulou F, Kompitsas M. Effects of experimental parameters in quantitative analysis of steel alloy by laser-induced breakdown spectroscopy. Spectrochimica Acta. Part B, Atomic Spectroscopy. 2001;56(6):671-683. http://dx.doi.org/10.1016/S0584-8547(01)00225-7.

16. Dell’Aglio M, De Giacomo A, Gaudiuso R, De Pascale O, Senesi GS, Longo S. Laser Induced Breakdown Spectroscopy applications to meteorites: Chemical analysis and composition profiles. Geochimica et Cosmochimica Acta. 2010;74(24):7329-7339. http://dx.doi.org/10.1016/j.gca.2010.09.018.

17. Tognoni E, Cristoforetti G, Legnaioli S, Palleschi V, Salvetti A, Mueller M, et al. A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma. Spectrochimica Acta B. 2007;62(12):1287-1302. http://dx.doi.org/10.1016/j.sab.2007.10.005.
588696fc7f8c9dd9008b47b9 tmm Articles
Links & Downloads

Tecnol. Metal. Mater. Min.

Share this page